Target
Gas |
Halogen
Gas |
Acid
Gas |
Organic
Vapors |
Ammonia |
Sulfur
Dioxide |
Hydrogen
Sulfide |
Ethylene
Oxide |
Formaldehyde |
Features |
Alphabets and Color Coding |
|
B |
C |
H |
S |
K |
|
|
|
Test
Gas |
Chlorine |
Hydrogen
Chloride |
Cyclohexane |
Ammonia |
Sulfur
Dioxide |
Hydrogen
Sulfide |
Ethylene
Oxide |
Formaldehyde |
|
|
Maximum
Permissible
Penetration Level
(Concentration) *1 |
|
1ppm |
5ppm |
5ppm |
50ppm |
5ppm |
10ppm |
1ppm |
0.08ppm
0.25ppm
|
|
|
Cartridge
Types |
Concentration of Test Gas |
|
Respirators for Use |
|
|
0.02%
(200ppm) |
0.03%
(300ppm) |
0.03%
(300ppm)
|
0.1%
(1000ppm)
|
0.03%
(300ppm)
|
0.02%
(200ppm)
|
0.003%
(30ppm)
|
0.02%
(20ppm)
|
|
|
R-5, RR-7 |
|
|
KGC-1M(C) for
organic vapors
Over 200 min. |
|
|
|
|
|
Light-weight,
low
airflow resistance |
|
R-5,
RR-7 |
KGC-1L(A) for halogen
gas
Over 250 min.
w/pre-filter (over 80.0%
filtering efficiency) |
KGC-1L(B) for acid gas
Over 430 min.
w/pre-filter (over 80.0%
filtering efficiency) |
KGC-1L(C) for
organic vapors
Over 260 min.
w/pre-filter (over 80.0%
filtering efficiency) |
KGC-1L(H)
for ammonia Over 140 min.
w/pre-filter (over 80.0%
filtering efficiency) |
KGC-1L(S)
for sulfur dioxide
Over 70 min.
w/pre-filter (over 80.0%
filtering efficiency) |
KGC-1L(K) for
hydrogen sulfide
Over 300 min.
w/pre-filter (over 80.0%
filtering efficiency) |
|
|
Long
service life,
particulate filtering
category S1
with the use of
pre-filter |
|
R-5,
RR-7 |
|
|
KGC-1S(C) for
organic vapors
Over 85 min.
w/pre-filter (over 80.0%
filtering efficiency) |
|
|
|
|
|
Light-weight,
low
profile, particulate
filtering category
S1 with the use of
pre-filter |
|
R-5,
RR-7 |
|
|
KGC-5MC
Over 85 min./Over
80.0% filtering efficiency) |
|
|
|
|
|
Low
profile,
built-in pre-filter
(category S1) |
|
G-7, GW-7 |
KGC-10(A) for halogen
gas
Over 100 min.
w/pre-filter (over 80.0%
filtering efficiency) |
KGC-10(B) for acid gas
Over 120 min.
w/pre-filter (over 80.0%
filtering efficiency) |
KGC-10(C) for
organic vapors
Over 90 min.
w/pre-filter (over 80.0%
filtering efficiency) |
|
|
|
KGC-10EOG
Over 30 min. |
KGC-10FA
Over 90 min. Over 250 min. |
Compact, light-weight,
threaded type, particulate
filtering category
S1 with the use of prefilter |
|
G-7,
GW-7 |
|
|
KGC-10L(C) for organic
vapors
Over 200 min.
w/pre-filter (over 80.0%
filtering efficiency) |
|
|
|
|
|
Compact,
light-weight,
threaded type, particulate
filtering category
S1 with the use of prefilter |
|
G-7,
GW-7 |
|
|
KGC-10MC
Over 80 min./Over
80.0% filtering efficiency |
|
|
|
|
|
Compact,
light-weight,
built-in prefilter
(category S1),
threaded type |